Skip to Main Content
SickKids

Basophil Activation Test (BAT)

Alternate test name

Basophil Degranulation Test

Lab area
Haematopathology
Method and equipment

Method: Flow CAST® Kit (BÜHLMANN) by Flow Cytometry

Equipment: BD FACSLyric

Expected turn-around time
5 business days
Specimen type

Whole blood

Storage and transportation

Do not spin. Do not aliquot. Store specimen at 4oC. Ship on ice. 

Specimen stability in Flow testing is only acceptable within 48 hours of collection if stored at 4oC, or 24 hours if stored at room temperature.

Special requirements

Ensure that at least four weeks have elapsed after an allergic reaction before collecting BAT.

Systemically administered antiallergenic drugs such as corticosteroids, chromoglycic acid (DSCG) should be avoided for at least 24 hours prior to blood sampling.

Interference with test results is expected for patients under omalizumab (XOLAIR®) therapy.

Shipping information
The Hospital for Sick Children
Rapid Response Laboratory
555 University Avenue, Room 3642
Toronto, ON
Canada
M5G 1X8
Phone: 416-813-7200
Toll Free: 1-855-381-3212
Hours: 7 days/week, 24 hours/day
Back to Top